UNDERSTAND IT. WORK IT OUT.

Learn: Steady radial flow — confined aquifer

The confined Thiem-type well relation connects steady radial flow with heads measured at two distances from a well. The radius order and head difference determine the sign of the result.

Beginner-friendlyFree · No accountTwo worked examples + separate practice
01

What the formula is saying

For constant aquifer thickness b, use 2πkb(h₁ − h₂)/ln(r₂/r₁). Here r₁ is the inner radius. The stored formula defines positive Q as outward radial flow; pumping toward the well normally gives h₁ < h₂ and a negative Q.

Q = 2π k b (h₁−h₂) / ln(r₂/r₁)

Read the symbols in plain language

k
Hydraulic conductivity

The soil/aquifer permeability parameter relating Darcy discharge velocity to hydraulic gradient under the stated flow conditions.

m/s

Use m/s as the base unit shown here. k is hydraulic conductivity in m/s; radii and piezometric heads h₁, h₂ and saturated thickness b use m. ln is the natural logarithm of the dimensionless radius ratio. Q is m³/s.

b
Aquifer thickness

Aquifer thickness. Combine conductivity, aquifer geometry and driving-head difference without hiding the flow sign.

m

Metres measure length; 1 m = 1000 mm.

h₁
Head at r₁

Head at r₁. Keep inner minus outer head in the stored formula; the sign reveals the modeled radial-flow direction.

m

Metres measure length; 1 m = 1000 mm.

h₂
Head at r₂

Head at r₂. Keep inner minus outer head in the stored formula; the sign reveals the modeled radial-flow direction.

m

Metres measure length; 1 m = 1000 mm.

r₁
Radius 1

Radial distance from the same well centre to the observation location; r2 must be greater than r1.

m

Metres measure length; 1 m = 1000 mm.

r₂
Radius 2

Radial distance from the same well centre to the observation location; r2 must be greater than r1.

m

Metres measure length; 1 m = 1000 mm.

Q
Result to find

Steady radial flow — confined aquifer. Combine conductivity, aquifer geometry and driving-head difference without hiding the flow sign.

m³/s

Sort out the units first

k is hydraulic conductivity in m/s; radii and piezometric heads h₁, h₂ and saturated thickness b use m. ln is the natural logarithm of the dimensionless radius ratio. Q is m³/s.

Assumptions before calculating

Assume steady radial flow in a homogeneous isotropic aquifer around a fully penetrating well, with no recharge between the two observation radii and negligible well losses. Require 0 < r₁ < r₂ and compatible head observations.

02

Let’s solve one together

Read the given values, follow each operation, then check what the result means.

Read the supplied values as one complete study case. Find Q and explain the result in the stated output unit.

k · Hydraulic conductivity
0.0001 m/s
b · Aquifer thickness
10 m
h₁ · Head at r₁
20 m
h₂ · Head at r₂
18 m
r₁ · Radius 1
1 m
r₂ · Radius 2
50 m
  1. Take the natural logarithm of the radius ratio

    The outer radius divided by the inner radius is greater than one, giving a positive logarithm.

    ln((50) ÷ (1)) ≈ 3.912023005
  2. Apply the stated outward-positive convention

    Keep inner minus outer head in the stored formula; the sign reveals the modeled radial-flow direction.

    (20)-(18) = 2 m
  3. Calculate the signed radial discharge

    Combine conductivity, aquifer geometry and driving-head difference without hiding the flow sign.

    2 × π × (0.0001) × (10) × (2) ÷ (3.912023005) ≈ 0.003212243537 m³/s
Answer0.003212243537 m³/s

Signed radial discharge, positive outward from the well and negative inward toward it.

Does this worked answer make sense?

Equal heads give zero radial flow. With r₂ > r₁, the logarithm is positive, so Q must follow the sign of h₁ − h₂. For a pumping-rate magnitude, report −Q only when the calculated Q is negative and explain the changed convention.

A second worked example — different values

A second case uses different data. Predict which way the answer will change, then calculate it without reusing the first answer.

k · Hydraulic conductivity
0.00015 m/s
b · Aquifer thickness
8 m
h₁ · Head at r₁
16 m
h₂ · Head at r₂
19 m
r₁ · Radius 1
2 m
r₂ · Radius 2
40 m
  1. Take the natural logarithm of the radius ratio

    The outer radius divided by the inner radius is greater than one, giving a positive logarithm.

    ln((40) ÷ (2)) ≈ 2.995732274
  2. Apply the stated outward-positive convention

    Keep inner minus outer head in the stored formula; the sign reveals the modeled radial-flow direction.

    (16)-(19) = -3 m
  3. Calculate the signed radial discharge

    Combine conductivity, aquifer geometry and driving-head difference without hiding the flow sign.

    2 × π × (0.00015) × (8) × (-3) ÷ (2.995732274) ≈ -0.007550563615 m³/s
Answer-0.007550563615 m³/s

Signed radial discharge, positive outward from the well and negative inward toward it.

03

Now try your own values

Change a value or its unit. The same method will show your calculation, step by step.

The soil/aquifer permeability parameter relating Darcy discharge velocity to hydraulic gradient under the stated flow conditions.

Aquifer thickness. Combine conductivity, aquifer geometry and driving-head difference without hiding the flow sign.

Head at r₁. Keep inner minus outer head in the stored formula; the sign reveals the modeled radial-flow direction.

Head at r₂. Keep inner minus outer head in the stored formula; the sign reveals the modeled radial-flow direction.

Radial distance from the same well centre to the observation location; r2 must be greater than r1.

Radial distance from the same well centre to the observation location; r2 must be greater than r1.

English, Arabic and Persian digits are supported. The steps convert inputs to the formula’s base units.

Results update only when you calculate. The lesson example above stays unchanged.

04

Your turn — check your understanding

Solve this separate case yourself. Use only the values below; the two worked examples use different data. Give the requested result in the selected unit.

k · Hydraulic conductivity
0.00008 m/s
b · Aquifer thickness
12 m
h₁ · Head at r₁
17 m
h₂ · Head at r₂
20 m
r₁ · Radius 1
1.5 m
r₂ · Radius 2
60 m

Find: Learn: Steady radial flow — confined aquifer

For repeating decimals, use at least four significant figures. Accepted rounding tolerance: 0.05% of the expected value; zero uses an absolute tolerance of 10⁻¹².

A hint, not the answer

For constant aquifer thickness b, use 2πkb(h₁ − h₂)/ln(r₂/r₁). Here r₁ is the inner radius. The stored formula defines positive Q as outward radial flow; pumping toward the well normally gives h₁ < h₂ and a negative Q.

k is hydraulic conductivity in m/s; radii and piezometric heads h₁, h₂ and saturated thickness b use m. ln is the natural logarithm of the dimensionless radius ratio. Q is m³/s.

Show the full practice solution

Compare the steps with your work; revealing a solution does not mark the lesson complete.

  1. Take the natural logarithm of the radius ratio

    The outer radius divided by the inner radius is greater than one, giving a positive logarithm.

    ln((60) ÷ (1.5)) ≈ 3.688879454
  2. Apply the stated outward-positive convention

    Keep inner minus outer head in the stored formula; the sign reveals the modeled radial-flow direction.

    (17)-(20) = -3 m
  3. Calculate the signed radial discharge

    Combine conductivity, aquifer geometry and driving-head difference without hiding the flow sign.

    2 × π × (0.00008) × (12) × (-3) ÷ (3.688879454) ≈ -0.004905439148 m³/s
Answer-0.004905439148 m³/s

Signed radial discharge, positive outward from the well and negative inward toward it.

Avoid the common trap

Do not silently reverse the head difference just to force a positive answer. Do not omit b or use the unconfined squared-head formula. Do not use log10 instead of ln.

When this method applies — and when it does not

The confined thickness is constant and the aquifer remains saturated. Head may use a common arbitrary datum because only its difference appears. This is not a transient pumping-test solution and does not handle boundaries, partial penetration, anisotropy or changing storage automatically.

For study and understanding, not approval of a real structure, site operation or design. Apply the correct standard, National Annex and professional review to actual engineering work.

One idea understood. Keep going.

This optional checkmark is saved only in this browser. It is your own progress note, not a certificate.

Sources & further reading

References open in a new tab and explain the underlying principles. The teaching text and examples here are SimpleFlick’s own; the source organisations have not endorsed this calculator.

Reading focus: Steady radial flow — confined aquifer. Steady radial well-flow / Thiem relationships. Match confined versus unconfined assumptions, radii, head datum and the lesson’s outward-positive sign convention.

Lesson updated: · Both examples and the separate practice case are checked against an independent high-precision numerical implementation. This verifies arithmetic for the stated model, not engineering certification.

Menu